Step 1.

Open the back cover.


How to disassemble Philips Xenium I908, Step 2/1 How to disassemble Philips Xenium I908, Step 2/2

Step 2.

Using a screwdriver (Phillips 1.5 mm PH000), unscrew 11 bolts in the frame of the phone.


How to disassemble Philips Xenium I908, Step 3/1 How to disassemble Philips Xenium I908, Step 3/2

Step 3.

Open the upper cover and remove the buzzer (speaker) assembly.


How to disassemble Philips Xenium I908, Step 4/1 How to disassemble Philips Xenium I908, Step 4/2 How to disassemble Philips Xenium I908, Step 4/3

Step 4.

Disconnect the battery connector.

⚠️ Warning!

We strongly recommend disconnecting the connector to avoid a possible short circuit during disassembly.


How to disassemble Philips Xenium I908, Step 5/1 How to disassemble Philips Xenium I908, Step 5/2

Step 5.

Using a screwdriver (Phillips 1.5 mm PH000), unscrew 2 bolts in the PCB.


How to disassemble Philips Xenium I908, Step 6/1 How to disassemble Philips Xenium I908, Step 6/2

Step 6.

Disconnect connector on the PCB and remove the main camera.


How to disassemble Philips Xenium I908, Step 7/1 How to disassemble Philips Xenium I908, Step 7/2 How to disassemble Philips Xenium I908, Step 7/3

Step 7.

Disconnect connectors on the PCB.


How to disassemble Philips Xenium I908, Step 8/1 How to disassemble Philips Xenium I908, Step 8/2

Step 8.

Remove the PCB.


How to disassemble Philips Xenium I908, Step 9/1 How to disassemble Philips Xenium I908, Step 9/2

Step 9.

Lift and remove the battery.


How to disassemble Philips Xenium I908, Step 10/1 How to disassemble Philips Xenium I908, Step 10/2

Step 10.

Remove the lower PCB with inter-board and coaxial cables.


How to disassemble Philips Xenium I908, Step 11/1 How to disassemble Philips Xenium I908, Step 11/2

Step 11.

Pry and remove the earpiece (speaker).


How to disassemble Philips Xenium I908, Step 12/1 How to disassemble Philips Xenium I908, Step 12/2 How to disassemble Philips Xenium I908, Step 12/3

Step 12.

Parts are in the frame of the display module.

Detailed disassembly instructions of Philips Xenium I908 in the video, made by our mobile repair & service center:

If you have a question, ask us, and we will try to answer in as much detail as possible. If this article was helpful for you, please rate it.


Disassembling\Repair has easy complexity and takes about 6 minutes in time.
Our manual is suitable for all models Philips Xenium I908 released for markets in different countries.




Back to the list
˄˅
˃˂